PowerTrans PT-7728 Series NEW!
24+4G-port Gigabit Modular Managed
Ethernet Switch |
|
 |
Industrial
Ethernet |
 |
|
|
 |
 |
IEC 61850-3, IEEE1613 (power
substations), NEMA TS2 (traffic
control
systems), and EN50121-4 (railway applications)
compliant |
 |
Turbo Ring and RSTP/STP for Ethernet
Redundancy |
 |
Universal power supply range, 24, 48
VDC or 110/220 VDC/VAC |
 |
Modular design lets you choose from a
variety of media
combinations |
 |
-40 to 85°C operating temperature
range |
| |
|
|
|
| |
 |
Introduction |
 |
|
| |
The PowerTrans PT-7728 is
designed to meet the demands of power substation
automation systems (IEC 61850-3, IEEE1613),
traffic control systems (NEMA TS2), and railway
applications (EN50121-4). The PT-7728’s gigabit
and fast Ethernet backbone, redundant ring, and
24/48 VDC or 110/220 VDC/VAC dual redundant power
supplies increase the reliability of your
communications and save on cabling/wiring costs.
The modular design of the PT-7728 also makes
network planning easy, and allows greater
flexibility by letting you install up to 4 gigabit
ports and 24 fast Ethernet ports. The optional
front or rear wiring makes the PT-7728 suitable
for a variety of applications.
|
|
| |
 |
Key
Features & Benefits |
 |
|
|
 |
Turbo Ring and RSTP/STP (IEEE
802.1W/D) |
 |
IGMP Snooping and GMRP for filtering
multicast traffic from industrial Ethernet
protocols |
 |
IEEE 802.1Q VLAN, and GVRP protocol to
ease network planning |
 |
QoS-IEEE802.1p/1Q and TOS/DiffServ to
increase determinism |
 |
802.3ad, LACP for optimum bandwidth
utilization |
 |
IEEE 802.1X and https/SSL to enhance
network security |
 |
SNMP V1/V2c/V3 for different levels of
network management |
 |
RMON for efficient network monitoring
and proactive capability |
 |
ABC-01 for system configuration
backup |
 |
Bandwidth management prevents
unpredictable network status with "Lock port" to
restrict access to authorized MAC
addresses |
 |
Port mirroring for online
debugging |
 |
Automatic warning by exception through
email, relay output |
 |
Automatic recovery of connected
device’s IP addresses |
 |
Line-swap fast recovery |
 |
Configurable by Web browser,
Telnet/Serial console, Windows utility, and
ABC-01 |
|
|
|
|
|
 |
Specifications
|
 |
|
|
| Modular Rackmount Switch System,
PT-7728 |
 |
| |
Technology |
|
|
IEEE
802.3 for 10BaseT,
IEEE 802.3u for
100BaseT(X) and 100Base FX,
IEEE 802.3ab for
1000BaseT(X),
IEEE 802.3z for
1000BaseSX/LX/LHX/ZX,
IEEE 802.3x for Flow
Control,
IEEE 802.1D for Spanning Tree
Protocol,
IEEE 802.1W for Rapid STP,
IEEE
802.1Q for VLAN Tagging,
IEEE 802.1p for
Class of Service,
IEEE 802.1X for
Authentication,
IEEE 802.3ad for Port Trunk
with
LACP |
|
|
|
IGMP V1/V2/V3 device, GMRP, GVRP, SNMP
V1/V2C/V3, DHCP Server/Client, DHCP Option 82,
BootP, TFTP, NTP, SMTP, RARP,
RMON
|
|
|
|
| MIB-II, Ethernet-like MIB, P-BRIDGE
MIB, Q-BRIDGE MIB, Bridge MIB, RSTP MIB, RMON
MIB Group 1, 2, 3,
9 |
|
|
|
| IEEE
802.3x flow control, back pressure flow
control |
|
|
|
|
|
| |
Interface |
|
|
| Slot
1, 2, 3 for any combination of 8-, 7-, or 6-port
interface module with 10/100BaseT(X) or
100BaseFX (SC/ST
connector) |
|
|
|
Slot 4 for 4- or 2-port interface module with
10/100/1000BaseT(X), 1000BaseSX/LX/LHX/ZX (LC
connector) |
|
|
|
|
|
| STAT, PWR1, PWR2, FAULT, MASTER,
COUPLER |
|
|
|
| LNK/ACT, FDX/HDX, RING PORT, COUPLER
PORT,
SPEED |
|
|
|
| one
relay output with current carrying capacity of
1A @ 24
VDC |
|
|
|
|
| |
Power
Requirements |
|
|
| 24
VDC (18 to 36 V), or 48 VDC (36 to 72 V), or
125/250 VDC (88 to 300 V) and 110/240 VAC (85 to
264
V) |
|
|
|
(all
ports are equipped with Fiber)
Max 2.58A @ 24
VDC,
Max 1.21A @ 48 VDC,
Max 0.53A @ 250
VDC or 240
VAC |
|
|
|
|
| Overload Current
Protection |
|
|
| Reverse Polarity
Protection |
|
|
|
|
| |
Physical
Characteristics |
|
|
| |
Environmental
Limits |
|
|
-40
to 85°C (-40 to 185°F)
cold start of min. 100
VAC at
-40°C |
|
|
|
| -40
to 85°C (-40 to
185°F) |
|
|
| Ambient Relative
Humidity |
|
| 5 to
95%
(non-condensing) |
|
|
|
|
| |
| Gigabit Ethernet
Interface Modules, PM-7200-4G/2G series |
 |
 |
PM-7200-4GTXSFP |
PM-7200-2GTXSFP |
|
Interface |
|
| 10/100/1000BaseT(X) auto negotiation
speed, and auto MDI/ MDI-X
connection |
|
|
|
| 1000BaseSX/LX/LHX/ZX (SFP slot, LC
connector) |
|
|
| * The
PM-7200-2G/4G series gigabit Ethernet modules
support 4 or 2 SFP slots. Please refer to page
2-xx to select the SFP-1G series gigabit
Ethernet modules that you need for your own
application. |
|
|
|
|
| |
| Fast Ethernet
Interface Modules, PM-7200 series |
 |
 |
 |
 |
PM-7200-8TX |
PM-7200-2MSC4TX
PM-7200-2SSC4TX |
PM-7200-2MST4TX |
PM-7200-4MSC2TX
PM-7200-4SSC2TX |
 |
 |
 |
 |
PM-7200-4MST2TX |
PM-7200-6MSC
PM-7200-6SSC |
PM-7200-6MST |
PM-7200-1LSC6TX |
|
Interface |
|
| 10/100BaseT(X) auto negotiation speed,
F/H duplex mode, and auto MDI/MDI-X
connection |
|
|
|
| 100BaseFX ports (SC/ST
connector) |
|
|
|
|
| |
|
| |
 |
Ordering
Information
|
 |
|
Ordering Process for
PT-7728 |
|
| |
Step 1: Select
switch system |
Step 2: Select
interface module |
 |
|
| |
Modular Rackmount Switch
System, PT-7728 |
|
|
| Modular
Managed Ethernet Switch System with 3 slots for
100 Mbps modules, 1 slot for Gbps modules,
Ethernet ports on front panel, LED display on
front panel, with one power supply of 24 VDC,
-40 to 85°C. |
|
|
| Modular Managed Ethernet Switch System
with 3 slots for 100 Mbps modules, and 1 slot
for Gbps modules, Ethernet ports on front panel,
LED display on front panel, with two 24 VDC
power supplies, -40 to
85°C. |
|
|
| Modular
Managed Ethernet Switch System with 3 slots for
100 Mbps modules, 1 slot for Gbps modules,
Ethernet ports on front panel, LED display on
front panel, with two power supplies of 24 VDC
and 48 VDC, -40 to
85°C. |
|
|
| Modular
Managed Ethernet Switch System with 3 slots for
100 Mbps modules, 1 slot for Gbps modules,
Ethernet ports on front panel, LED display on
front panel, with two power supplies of 24 VDC
and 88 to 300 VDC or 85 to 264 VAC, -40 to
85°C. |
|
|
| Modular Managed Ethernet Switch System
with 3 slots for 100 Mbps modules, 1 slot for
Gbps modules, Ethernet ports on front panel, LED
display on front panel, with one power supply of
48 VDC, -40 to
85°C. |
|
|
| Modular Managed Ethernet Switch System
with 3 slots for 100 Mbps modules, 1 slot for
Gbps modules, Ethernet ports on front panel, LED
display on front panel, with two 48 VDC power
supplies, -40 to
85°C. |
|
|
| Modular
Managed Ethernet Switch System with 3 slots for
100 Mbps modules, 1 slot for Gbps modules,
Ethernet ports on front panel, LED display on
front panel, with two power supplies of 48 VDC
and 88 to 300 VDC or 85 to 264 VAC, -40 to
85°C. |
|
|
| Modular
Managed Ethernet Switch System with 3 slots for
100 Mbps modules, 1 slot for Gbps modules,
Ethernet ports on front panel, LED display on
front panel, with one power supply of 88 to 300
VDC or 85 to 264 VAC, -40 to
85°C. |
|
|
| Modular
Managed Ethernet Switch System with 3 slots for
100 Mbps modules, 1 slot for Gbps modules,
Ethernet ports on front panel, LED display on
front panel, with two 88 to 300 VDC or 85 to 264
VAC power supplies, -40 to
85°C. |
|
|
| Modular Managed Ethernet Switch System
with 3 slots for 100 Mbps modules, 1 slot for
Gbps modules, Ethernet ports on rear panel, LED
display on front panel, with one power supply of
24 VDC, -40 to
85°C. |
|
|
| Modular Managed Ethernet Switch System
with 3 slots for 100 Mbps modules, and 1 slot
for Gbps modules, Ethernet ports on rear panel,
LED display on front panel, with two 24 VDC
power supplies, -40 to
85°C. |
|
|
| Modular
Managed Ethernet Switch System with 3 slots for
100 Mbps modules, 1 slot for Gbps modules,
Ethernet ports on rear panel, LED display on
front panel, with two power supplies of 24 VDC
and 48 VDC, -40 to
85°C. |
|
|
| Modular
Managed Ethernet Switch System with 3 slots for
100 Mbps modules, 1 slot for Gbps modules,
Ethernet ports on rear panel, LED display on
front panel, with two power supplies of 24 VDC
and 88 to 300 VDC or 85 to 264 VAC, -40 to
85°C. |
|
|
| Modular Managed Ethernet Switch System
with 3 slots for 100 Mbps modules, 1 slot for
Gbps modules, Ethernet ports on rear panel, LED
display on front panel, with one power supply of
48 VDC, -40 to
85°C. |
|
|
| Modular Managed Ethernet Switch System
with 3 slots for 100 Mbps modules, 1 slot for
Gbps modules, Ethernet ports on rear panel, LED
display on front panel, with two 48 VDC power
supplies, -40 to
85°C. |
|
|
| Modular
Managed Ethernet Switch System with 3 slots for
100 Mbps modules, 1 slot for Gbps modules,
Ethernet ports on rear panel, LED display on
front panel, with two power supplies of 48 VDC
and 88 to 300 VDC or 85 to 264 VAC, -40 to
85°C. |
|
|
| Modular
Managed Ethernet Switch System with 3 slots for
100 Mbps modules, 1 slot for Gbps modules,
Ethernet ports on rear panel, LED display on
front panel, with one power supply of 88 to 300
VDC or 85 to 264 VAC, -40 to
85°C. |
|
| | | |